1125rcya
Posted on Sunday, August 15, 2010 - 11:41 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

All stock...09 1125R...4600 miles...harness up grade at 4100 miles...
I was riding today and then all the sudden I received this error. No speed, no turn signals, I couldn't stop because there was traffic behind me on a country road. I took this quick picture. I finally made it to a gas station then got batt. light shut the bike down restarted after about 3mins and all was good...WoW...just a glitch?

Top of pagePrevious messageNext messageBottom of page Link to this message

Dktechguy112
Posted on Monday, August 16, 2010 - 02:15 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

its probably the voltage regulator. check the voltage, if it goes up to 15 or 16 volts then its your voltage regulator. could be stator going out as well, the system voltage error comes up if the voltage goes to high or to low. If its going to high, then its probably the voltage regulator, if it is going to low, then it is probably the stator.
Top of pagePrevious messageNext messageBottom of page Link to this message

Rob_l
Posted on Monday, August 16, 2010 - 08:07 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

The same thing happened to my 1125R. I always toggle to coolant temp. and voltage output before starting out. It would act just as you say and I could also hear the alternator whining but I just kept riding and after a mile or so the IP would come back on and the voltage would be 17 to 16 then drop back down and the whining stopped. Dealer replaced voltage Regulator all has been fine sense.
Top of pagePrevious messageNext messageBottom of page Link to this message

Daniii
Posted on Monday, August 16, 2010 - 11:50 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Guess I'll be taking the bike to the dealer for a new voltage regulator....
Top of pagePrevious messageNext messageBottom of page Link to this message

Bextreme04
Posted on Monday, August 16, 2010 - 12:06 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Mine does the same thing, going into the dealer for a new voltage regulator tomorrow... It has done it since i got it with around 2,000 miles on it and i have put about 1,000 more since then, it usually happens when i rev it up near redline near the start of a ride i just kill it and start it back up whenever it happens and it is usually fine afterwards but the voltage can be as high as 19v when i shut it off and then it goes back down to 13.9 or so.
« Previous Next »

Add Your Message Here
Post:
Bold text Italics Underline Create a hyperlink Insert a clipart image

Username: Posting Information:
This is a public posting area. Enter your username and password if you have an account. Otherwise, enter your full name as your username and leave the password blank. Your e-mail address is optional.
Password:
E-mail:
Options: Post as "Anonymous" (Valid reason required. Abusers will be exposed. If unsure, ask.)
Enable HTML code in message
Automatically activate URLs in message
Action:

Topics | Last Day | Tree View | Search | User List | Help/Instructions | Rules | Program Credits Administration