Author |
Message |
Buellish
| Posted on Monday, August 14, 2017 - 07:05 pm: |
|
Has anyone found an alternative O2 sensor or a cross referenced part number for the one used on the injected tubers? |
Two_seasons
| Posted on Monday, August 14, 2017 - 07:13 pm: |
|
Ford Mustang is OEM replacement. Take old one in to AutoZone, Advance, Napa. |
Loose1
| Posted on Monday, August 14, 2017 - 07:22 pm: |
|
I've always use 88-95 chevy truck sensors. o2 sensor GM=25162693 NTK= 21002 Airtex= 553071 Bosch= 12014 Denso= 234-1001 Walker= 250-21001 SNG= SN1-15 Union Sangyo[OEM Toyota Mfg]#C-170. |
Ebutch
| Posted on Monday, August 14, 2017 - 08:55 pm: |
|
I USE Bosch #12014 same as above.$17.00 NAPA. (Message edited by ebutch on August 14, 2017) |
Buellish
| Posted on Monday, August 14, 2017 - 09:03 pm: |
|
Thanks guys,I'll round one up tomorrow and see if that makes a difference. |
Ebutch
| Posted on Monday, August 14, 2017 - 09:11 pm: |
|
Also exost leak heads to header kills 02 senser! New header gaskets too. (Message edited by ebutch on August 14, 2017) |
Williamscottrobertson
| Posted on Tuesday, August 15, 2017 - 12:09 am: |
|
Beck arnley 156-8100 can be had for $20-30. Whichever you choose, if you cut the old connector off, solder it to the new sensor. Do not use crimp connections on any DDFI component. The resistance of the connection can cause bad readings. |
Wolfridgerider
| Posted on Tuesday, August 15, 2017 - 12:12 pm: |
|
Bosch 02 sensor part #12014 can be had for $11.49 on Amazon Prime |
Buellish
| Posted on Tuesday, August 15, 2017 - 12:13 pm: |
|
Well,so far I've not been able to remove the sensor.I let it soak in penetrant for an hour and used one of those O2 sockets that are split to accommodate the wire, with a hose clamp to keep it from slipping.I used it before successfully when I ceramic coated the head pipe but this time it slipped no matter how tight I had the clamp,it wouldn't hold.I didn't want to have to pull the head pipe but it looks like that's the only way to remove it. |
Ebutch
| Posted on Tuesday, August 15, 2017 - 12:31 pm: |
|
email me and I will loan you special socket. |
Ebutch
| Posted on Tuesday, August 15, 2017 - 01:13 pm: |
|
o2 socket & IM http://s144.photobucket.com/user/ebutch/media/100_ 0891.jpg.html Direct http://i144.photobucket.com/albums/r200/ebutch/100 _0891.jpg HTML <img> IMG O |
Akbuell
| Posted on Tuesday, August 15, 2017 - 02:38 pm: |
|
One thought- since you can get a socket on the old sensor, perhaps cutting the wire off and using a standard socket would work. Unless you have some use for the old one . . . Hope this helps, Dave |
Buellish
| Posted on Tuesday, August 15, 2017 - 03:32 pm: |
|
Butch,as I said above I used a socket just like the one in the image and it slipped,but thanks for the offer! David,I don't know why I'm so concerned about saving the wire,I'll cut it and see what happens. |
Natexlh1000
| Posted on Tuesday, August 15, 2017 - 03:38 pm: |
|
Can't you just use a box-end wrench? Just feed the wire through the opening. |
Ebutch
| Posted on Tuesday, August 15, 2017 - 05:11 pm: |
|
you will need connector off old o2 sensor for new 1 & soder on. try heat mapp gas and pencil-tip nozzle to break-free.Heat flange on header then use special socket to break-free. (Message edited by ebutch on August 15, 2017) |